NWIPB OpenIR
Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS
You, JM; Chen, XM; Zhao, XN; Su, YR; Wang, HL; Li, YL; Sun, J
2006-04-01
发表期刊CHROMATOGRAPHIA
卷号63期号:7-8页码:337-343
文章类型Article
摘要A pre-column derivatization method for the sensitive determination of amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate (BCIC-Cl) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives is carried out by high performance liquid chromatography/atmospheric pressure chemical ionization (LC-APCl-MS-MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent is replaced by 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl functional group, which results in a sensitive fluorescence derivatizing reagent BCIC-Cl. BCIC-Cl can easily and quickly label amines. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography and show an intense protonated molecular ion corresponding m/z [MH](+) under APCl in positive-ion mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 260 corresponding to the cleavage of CH2-OCO bond. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3 to 4-fold molar reagent excess. In addition, the detection responses for BCIC derivatives are compared with those obtained using CEOC and FMOC as derivatization reagents. The ratios of l(BCIC)/l(CEOC) and l(BCIC)/l(FMOC) are, respectively, 1.23-3.14 and 1.25-3.08 for fluorescent (FL) responses (here, l is relative fluorescence intensity). Separation of the derivatized amines had been optimized on reversed-phase Eclipse XDB-C-8 column. Detection limits are calculated from 1.0 pmol injection, at a signal-to-noise ratio of 3, are 10.6-37.8 fmol. The mean interday accuracy ranges from 94 to 105% for fluorescence detection with the largest mean %CV < 7.5. The mean interday precision for all standards is < 6.0% of the expected concentration. Excellent linear responses are observed with coefficients of > 0.9997.; A pre-column derivatization method for the sensitive determination of amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate (BCIC-Cl) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives is carried out by high performance liquid chromatography/atmospheric pressure chemical ionization (LC-APCl-MS-MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent is replaced by 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl functional group, which results in a sensitive fluorescence derivatizing reagent BCIC-Cl. BCIC-Cl can easily and quickly label amines. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography and show an intense protonated molecular ion corresponding m/z [MH](+) under APCl in positive-ion mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 260 corresponding to the cleavage of CH2-OCO bond. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3 to 4-fold molar reagent excess. In addition, the detection responses for BCIC derivatives are compared with those obtained using CEOC and FMOC as derivatization reagents. The ratios of l(BCIC)/l(CEOC) and l(BCIC)/l(FMOC) are, respectively, 1.23-3.14 and 1.25-3.08 for fluorescent (FL) responses (here, l is relative fluorescence intensity). Separation of the derivatized amines had been optimized on reversed-phase Eclipse XDB-C-8 column. Detection limits are calculated from 1.0 pmol injection, at a signal-to-noise ratio of 3, are 10.6-37.8 fmol. The mean interday accuracy ranges from 94 to 105% for fluorescence detection with the largest mean %CV < 7.5. The mean interday precision for all standards is < 6.0% of the expected concentration. Excellent linear responses are observed with coefficients of > 0.9997.
关键词Column Liquid Chromatography Derivatization Amines 1 2-benzo-3 4-dihydrocarbazole-9-isopropyl Chloroformate
WOS标题词Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences
学科领域生物化学
关键词[WOS]PERFORMANCE LIQUID-CHROMATOGRAPHY ; SOLID-PHASE MICROEXTRACTION ; SECONDARY ALIPHATIC-AMINES ; MASS-SPECTROMETRY ; WASTE-WATER ; 9-FLUORENYLMETHYL CHLOROFORMATE ; REAGENT ; ACIDS ; METHANOL ; CHLORIDE
收录类别SCI
语种英语
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS记录号WOS:000237350900007
引用统计
被引频次:7[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/1333
专题中国科学院西北高原生物研究所
作者单位1.Chinese Acad Sci, NW Plateau Inst Biol, Xining, Peoples R China
2.Qufu Normal Univ, Coll Chem Sci, Shandong 273165, Peoples R China
推荐引用方式
GB/T 7714
You, JM,Chen, XM,Zhao, XN,et al. Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS[J]. CHROMATOGRAPHIA,2006,63(7-8):337-343.
APA You, JM.,Chen, XM.,Zhao, XN.,Su, YR.,Wang, HL.,...&Sun, J.(2006).Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS.CHROMATOGRAPHIA,63(7-8),337-343.
MLA You, JM,et al."Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS".CHROMATOGRAPHIA 63.7-8(2006):337-343.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Pre-column derivatiz(306KB) 开放获取使用许可浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[You, JM]的文章
[Chen, XM]的文章
[Zhao, XN]的文章
百度学术
百度学术中相似的文章
[You, JM]的文章
[Chen, XM]的文章
[Zhao, XN]的文章
必应学术
必应学术中相似的文章
[You, JM]的文章
[Chen, XM]的文章
[Zhao, XN]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。