NWIPB OpenIR
Determination of Free Aliphatic Amines in Environmental Water by EASC Derivatization and Identification with LC-APCI-MS
Zhao Huai-Xin1; Sun Xue-Jun1; Sun Zhi-Wei2,3; Yan Tao1; Zhang Zai-Qing1; Liu Qin-Ze1; Suo You-Rui2; Li Yu-Lin2; You Jin-Mao1,2
2009-04-10
发表期刊CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE
ISSN0251-0790
卷号30期号:4页码:675-681
文章类型Article
摘要On a reversed-phase Hypersil BDS C(18) (4.6 mm x 200 mm, 10 mu m i.d.) column, 12 aliphatic amines were derivatized using 10-ethyl-9-oxo-9,10-dihydroacriditie-2-sulfonyl chloride(EASC) as a new pre-column derivatization reagent. The complete baseline resolution was obtained in conjunction with a gradient elution with acetonitrile/H(2)O as mobile phase within 20 min. The optimum excitation and emission wavelengths were at lambda(ex)/lambda(em) = 270 nm/430 nm. Comparing with the widely used Dansyl-Cl, EASC has stronger photoluminescence characteristics(ultraviolet and fluorescence) : UV(EASC)/UV(Dansyl-Cl) = 3.2 (UV: ultraviolet absorption intensity); I(EASC/I(Dansyl-Cl) = 30.0: 1-105. 4:1 (I: relative fluorescence intensity); fluorescence quantum yield: Phi(f)(EASC)/Phi(f)(Dansyl-Cl) = 43.0:1. Fast and accurate quantitative analysis of aliphatic amines with fluorescence and corresponding post-column ion trap mass spectrometry(LC-APCI-MS) were obtained. EASC-amines exhibited stronger mass spectrometric sensitivity relative to that of dansyl-amine derivatives: MS(EASC)/MS(Dansyl-Cl) = 1. 6: 1-6. 2: 1 times(MS: relative intensity of ion current). The established method for the determination of aliphatic amines in environmental water samples exhibited good reproducibility and recovery. Excellent linear responses were observed with the correlation coefficients >0.9995. The detection limits(at signal-to-noise of 3: 1) were at levels of 4.0-12.7 fmol.; On a reversed-phase Hypersil BDS C(18) (4.6 mm x 200 mm, 10 mu m i.d.) column, 12 aliphatic amines were derivatized using 10-ethyl-9-oxo-9,10-dihydroacriditie-2-sulfonyl chloride(EASC) as a new pre-column derivatization reagent. The complete baseline resolution was obtained in conjunction with a gradient elution with acetonitrile/H(2)O as mobile phase within 20 min. The optimum excitation and emission wavelengths were at lambda(ex)/lambda(em) = 270 nm/430 nm. Comparing with the widely used Dansyl-Cl, EASC has stronger photoluminescence characteristics(ultraviolet and fluorescence) : UV(EASC)/UV(Dansyl-Cl) = 3.2 (UV: ultraviolet absorption intensity); I(EASC/I(Dansyl-Cl) = 30.0: 1-105. 4:1 (I: relative fluorescence intensity); fluorescence quantum yield: Phi(f)(EASC)/Phi(f)(Dansyl-Cl) = 43.0:1. Fast and accurate quantitative analysis of aliphatic amines with fluorescence and corresponding post-column ion trap mass spectrometry(LC-APCI-MS) were obtained. EASC-amines exhibited stronger mass spectrometric sensitivity relative to that of dansyl-amine derivatives: MS(EASC)/MS(Dansyl-Cl) = 1. 6: 1-6. 2: 1 times(MS: relative intensity of ion current). The established method for the determination of aliphatic amines in environmental water samples exhibited good reproducibility and recovery. Excellent linear responses were observed with the correlation coefficients >0.9995. The detection limits(at signal-to-noise of 3: 1) were at levels of 4.0-12.7 fmol.
关键词High Performance Liquid Chromatography/ion-trap Mass Spectrometry Fluorescence Detection Pre-column Derivatization Aliphatic Amine 10-ethyl-9-oxo-9 10-dihydroacridine-2-sulfonyl Chloride
WOS标题词Science & Technology ; Physical Sciences
关键词[WOS]PERFORMANCE LIQUID-CHROMATOGRAPHY ; DANSYL CHLORIDE ; PRECOLUMN DERIVATIZATION ; FLUORESCENCE DETECTION ; DERIVATIVES ; IONIZATION
收录类别SCI
语种英语
WOS研究方向Chemistry
WOS类目Chemistry, Multidisciplinary
WOS记录号WOS:000265665700007
引用统计
被引频次:2[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/1886
专题中国科学院西北高原生物研究所
作者单位1.Qufu Normal Univ, Coll Chem Sci, Key Lab Life Organ Anal Shandony, Qufu 273165, Peoples R China
2.Chinese Acad Sci, NW Plateau Inst Biol, Xining 810001, Peoples R China
3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhao Huai-Xin,Sun Xue-Jun,Sun Zhi-Wei,et al. Determination of Free Aliphatic Amines in Environmental Water by EASC Derivatization and Identification with LC-APCI-MS[J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE,2009,30(4):675-681.
APA Zhao Huai-Xin.,Sun Xue-Jun.,Sun Zhi-Wei.,Yan Tao.,Zhang Zai-Qing.,...&You Jin-Mao.(2009).Determination of Free Aliphatic Amines in Environmental Water by EASC Derivatization and Identification with LC-APCI-MS.CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE,30(4),675-681.
MLA Zhao Huai-Xin,et al."Determination of Free Aliphatic Amines in Environmental Water by EASC Derivatization and Identification with LC-APCI-MS".CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE 30.4(2009):675-681.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhao Huai-Xin]的文章
[Sun Xue-Jun]的文章
[Sun Zhi-Wei]的文章
百度学术
百度学术中相似的文章
[Zhao Huai-Xin]的文章
[Sun Xue-Jun]的文章
[Sun Zhi-Wei]的文章
必应学术
必应学术中相似的文章
[Zhao Huai-Xin]的文章
[Sun Xue-Jun]的文章
[Sun Zhi-Wei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。