NWIPB OpenIR
2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemical ionization
You, JM ; Zhao, XN ; Suo, YR ; Wang, HL ; Li, YL ; Sun, J
2006-04-21
发表期刊ANALYTICA CHIMICA ACTA ; You Jinmao, Zhao Xianen, Suo Yourui, Wang Honglun, Li Yulin, Sun Jing.2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemical ionization.ANALYTICA CHIMICA ACTA,2006,565(2):168-177
摘要A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC-HCI) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at lambda(ex) 260nm and an emission maximum at lambda(em) 380nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH](+) under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C-8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were < 3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of > 0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory. (c) 2006 Elsevier B.V. All rights reserved.; A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC-HCI) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at lambda(ex) 260nm and an emission maximum at lambda(em) 380nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH](+) under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C-8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were < 3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of > 0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory. (c) 2006 Elsevier B.V. All rights reserved.
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/25362
专题中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
You, JM,Zhao, XN,Suo, YR,et al. 2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemical ionization[J]. ANALYTICA CHIMICA ACTA, You Jinmao, Zhao Xianen, Suo Yourui, Wang Honglun, Li Yulin, Sun Jing.2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemical ionization.ANALYTICA CHIMICA ACTA,2006,565(2):168-177,2006.
APA You, JM,Zhao, XN,Suo, YR,Wang, HL,Li, YL,&Sun, J.(2006).2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemical ionization.ANALYTICA CHIMICA ACTA.
MLA You, JM,et al."2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and its application for determination of amines by high performance liquid chromatography with fluorescence detection and identification with mass spectroscopy/atmospheric pressure chemical ionization".ANALYTICA CHIMICA ACTA (2006).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[You, JM]的文章
[Zhao, XN]的文章
[Suo, YR]的文章
百度学术
百度学术中相似的文章
[You, JM]的文章
[Zhao, XN]的文章
[Suo, YR]的文章
必应学术
必应学术中相似的文章
[You, JM]的文章
[Zhao, XN]的文章
[Suo, YR]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。