Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS
You, JM ; Chen, XM ; Zhao, XN ; Su, YR ; Wang, HL ; Li, YL ; Sun, J
2006-04-01
发表期刊CHROMATOGRAPHIA ; You Jinmao, Chen Xiangming, Zhao Xianen, Su Yourui, Wang Honglun, Li Yulin, Sun Jing.Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS. CHROMATOGRAPHIA,2006,63(7-8):337-343
摘要A pre-column derivatization method for the sensitive determination of amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate (BCIC-Cl) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives is carried out by high performance liquid chromatography/atmospheric pressure chemical ionization (LC-APCl-MS-MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent is replaced by 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl functional group, which results in a sensitive fluorescence derivatizing reagent BCIC-Cl. BCIC-Cl can easily and quickly label amines. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography and show an intense protonated molecular ion corresponding m/z [MH](+) under APCl in positive-ion mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 260 corresponding to the cleavage of CH2-OCO bond. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3 to 4-fold molar reagent excess. In addition, the detection responses for BCIC derivatives are compared with those obtained using CEOC and FMOC as derivatization reagents. The ratios of l(BCIC)/l(CEOC) and l(BCIC)/l(FMOC) are, respectively, 1.23-3.14 and 1.25-3.08 for fluorescent (FL) responses (here, l is relative fluorescence intensity). Separation of the derivatized amines had been optimized on reversed-phase Eclipse XDB-C-8 column. Detection limits are calculated from 1.0 pmol injection, at a signal-to-noise ratio of 3, are 10.6-37.8 fmol. The mean interday accuracy ranges from 94 to 105% for fluorescence detection with the largest mean %CV < 7.5. The mean interday precision for all standards is < 6.0% of the expected concentration. Excellent linear responses are observed with coefficients of > 0.9997.; A pre-column derivatization method for the sensitive determination of amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate (BCIC-Cl) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives is carried out by high performance liquid chromatography/atmospheric pressure chemical ionization (LC-APCl-MS-MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent is replaced by 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl functional group, which results in a sensitive fluorescence derivatizing reagent BCIC-Cl. BCIC-Cl can easily and quickly label amines. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography and show an intense protonated molecular ion corresponding m/z [MH](+) under APCl in positive-ion mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 260 corresponding to the cleavage of CH2-OCO bond. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0-10.0. Maximal yields close to 100% are observed with a 3 to 4-fold molar reagent excess. In addition, the detection responses for BCIC derivatives are compared with those obtained using CEOC and FMOC as derivatization reagents. The ratios of l(BCIC)/l(CEOC) and l(BCIC)/l(FMOC) are, respectively, 1.23-3.14 and 1.25-3.08 for fluorescent (FL) responses (here, l is relative fluorescence intensity). Separation of the derivatized amines had been optimized on reversed-phase Eclipse XDB-C-8 column. Detection limits are calculated from 1.0 pmol injection, at a signal-to-noise ratio of 3, are 10.6-37.8 fmol. The mean interday accuracy ranges from 94 to 105% for fluorescence detection with the largest mean %CV < 7.5. The mean interday precision for all standards is < 6.0% of the expected concentration. Excellent linear responses are observed with coefficients of > 0.9997.
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/40649
专题中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
You, JM,Chen, XM,Zhao, XN,et al. Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS[J]. CHROMATOGRAPHIA, You Jinmao, Chen Xiangming, Zhao Xianen, Su Yourui, Wang Honglun, Li Yulin, Sun Jing.Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS. CHROMATOGRAPHIA,2006,63(7-8):337-343,2006.
APA You, JM.,Chen, XM.,Zhao, XN.,Su, YR.,Wang, HL.,...&Sun, J.(2006).Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS.CHROMATOGRAPHIA.
MLA You, JM,et al."Pre-column derivatization of amines with 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate followed by LC-fluorescence and LC-APCI-MS".CHROMATOGRAPHIA (2006).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[You, JM]的文章
[Chen, XM]的文章
[Zhao, XN]的文章
百度学术
百度学术中相似的文章
[You, JM]的文章
[Chen, XM]的文章
[Zhao, XN]的文章
必应学术
必应学术中相似的文章
[You, JM]的文章
[Chen, XM]的文章
[Zhao, XN]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。