NWIPB OpenIR
CE determination of 2-(9-carbazole)ethyl chloroformate-labeled oligopeptides
Ding, Chenxu ; Sun, Xuejun ; Zhao, Xianen ; Zhao, Wenchen ; Li, Yulin ; Wang, Honglun ; Suo, Yourui ; You, Jinmao
2008-02-01
发表期刊CHROMATOGRAPHIA ; Ding Chenxu,Sun Xuejun,Zhao Xianen,Zhao Wenchen,Li Yulin, Wang Honglun,Suo Yourui,You Jinmao.CE determination of 2-(9-carbazole)ethyl chloroformate-labeled oligopeptides.CHROMATOGRAPHIA,2008,67(3-4):245-251
摘要A pre-column derivatization method for sensitive determination of oligopeptides, using the tagging reagent 2-(9-carbazole)ethyl chloroformate (CEOC-Cl) followed by capillary electrophoresis (CE) with diode-array detection, has been developed. Maximum yield close to 100% were observed when a three to fourfold molar excess of reagent was used at pH 9.0-10.0. Excess reagent was extracted with n-hexane-ethyl acetate 9:1-10:1 (v/v); this enabled direct analysis using CE with no significant disturbance from the major fluorescent reagent degradation by-products. The effects on the results of buffer pH and of SDS and organic modifier concentrations were examined. Good baseline resolution in the separation of five CEOC-peptides was achieved with a 48.5-cm total length (effective length 40 cm) 50-mu m inner diameter capillary column.; A pre-column derivatization method for sensitive determination of oligopeptides, using the tagging reagent 2-(9-carbazole)ethyl chloroformate (CEOC-Cl) followed by capillary electrophoresis (CE) with diode-array detection, has been developed. Maximum yield close to 100% were observed when a three to fourfold molar excess of reagent was used at pH 9.0-10.0. Excess reagent was extracted with n-hexane-ethyl acetate 9:1-10:1 (v/v); this enabled direct analysis using CE with no significant disturbance from the major fluorescent reagent degradation by-products. The effects on the results of buffer pH and of SDS and organic modifier concentrations were examined. Good baseline resolution in the separation of five CEOC-peptides was achieved with a 48.5-cm total length (effective length 40 cm) 50-mu m inner diameter capillary column.
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/45634
专题中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Ding, Chenxu,Sun, Xuejun,Zhao, Xianen,et al. CE determination of 2-(9-carbazole)ethyl chloroformate-labeled oligopeptides[J]. CHROMATOGRAPHIA, Ding Chenxu,Sun Xuejun,Zhao Xianen,Zhao Wenchen,Li Yulin, Wang Honglun,Suo Yourui,You Jinmao.CE determination of 2-(9-carbazole)ethyl chloroformate-labeled oligopeptides.CHROMATOGRAPHIA,2008,67(3-4):245-251,2008.
APA Ding, Chenxu.,Sun, Xuejun.,Zhao, Xianen.,Zhao, Wenchen.,Li, Yulin.,...&You, Jinmao.(2008).CE determination of 2-(9-carbazole)ethyl chloroformate-labeled oligopeptides.CHROMATOGRAPHIA.
MLA Ding, Chenxu,et al."CE determination of 2-(9-carbazole)ethyl chloroformate-labeled oligopeptides".CHROMATOGRAPHIA (2008).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Ding, Chenxu]的文章
[Sun, Xuejun]的文章
[Zhao, Xianen]的文章
百度学术
百度学术中相似的文章
[Ding, Chenxu]的文章
[Sun, Xuejun]的文章
[Zhao, Xianen]的文章
必应学术
必应学术中相似的文章
[Ding, Chenxu]的文章
[Sun, Xuejun]的文章
[Zhao, Xianen]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。