NWIPB OpenIR
Application of 10-ethyl-acridine-3-sulfonyl chloride for HPLC determination of aliphatic amines in environmental water using fluorescence and APCI-MS
You, Jinmao ; Zhao, Huaixin ; Sun, Zhiwei ; Xia, Lian ; Yan, Tao ; Suo, Yourui ; Li, Yulin
2009-05-01
发表期刊JOURNAL OF SEPARATION SCIENCE ; You, JM; Zhao, HX; Sun, ZW; Xia, L; Yan, T; Suo, YR; Li, YL.Application of 10-ethyl-acridine-3-sulfonyl chloride for HPLC determination of aliphatic amines in environmental water using fluorescence and APCI-MS,JOURNAL OF SEPARATION SCIENCE,2009,32(9):1351-1362
摘要A simple, sensitive method for the determination of aliphatic amines based on a sulfonylation reaction using 10-ethyl-acridine-3-sulfonyl chloride (EASC) as pre-column labeling reagent with fluorescence detection and APCI-MS identification has been developed. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by HPLC with an excitation maximum at lambda(ex) 270 nm and an emission maximum at lambda(em) 430 nm. Identification of derivatives was carried out by online post-column MS in positive-ion mode. Comparing with the widely used 5-dimethylaminonaphthalene-1-sulfonylchloride (Dansyl-Cl), EASC-amine derivatives not only exhibited high fluorescence but also exhibited excellent MS ionizable potential. Detection limits obtained from 0.10 pmol injection, at a S/N of 3, were 4.0-12.7 fmol. The mean intra- and inter-assay precision for all aliphatic amine levels were <3.84 and 3.21%, respectively. Excellent linear responses were observed with coefficients of >0.9995.; A simple, sensitive method for the determination of aliphatic amines based on a sulfonylation reaction using 10-ethyl-acridine-3-sulfonyl chloride (EASC) as pre-column labeling reagent with fluorescence detection and APCI-MS identification has been developed. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by HPLC with an excitation maximum at lambda(ex) 270 nm and an emission maximum at lambda(em) 430 nm. Identification of derivatives was carried out by online post-column MS in positive-ion mode. Comparing with the widely used 5-dimethylaminonaphthalene-1-sulfonylchloride (Dansyl-Cl), EASC-amine derivatives not only exhibited high fluorescence but also exhibited excellent MS ionizable potential. Detection limits obtained from 0.10 pmol injection, at a S/N of 3, were 4.0-12.7 fmol. The mean intra- and inter-assay precision for all aliphatic amine levels were <3.84 and 3.21%, respectively. Excellent linear responses were observed with coefficients of >0.9995.
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/51159
专题中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
You, Jinmao,Zhao, Huaixin,Sun, Zhiwei,et al. Application of 10-ethyl-acridine-3-sulfonyl chloride for HPLC determination of aliphatic amines in environmental water using fluorescence and APCI-MS[J]. JOURNAL OF SEPARATION SCIENCE, You, JM; Zhao, HX; Sun, ZW; Xia, L; Yan, T; Suo, YR; Li, YL.Application of 10-ethyl-acridine-3-sulfonyl chloride for HPLC determination of aliphatic amines in environmental water using fluorescence and APCI-MS,JOURNAL OF SEPARATION SCIENCE,2009,32(9):1351-1362,2009.
APA You, Jinmao.,Zhao, Huaixin.,Sun, Zhiwei.,Xia, Lian.,Yan, Tao.,...&Li, Yulin.(2009).Application of 10-ethyl-acridine-3-sulfonyl chloride for HPLC determination of aliphatic amines in environmental water using fluorescence and APCI-MS.JOURNAL OF SEPARATION SCIENCE.
MLA You, Jinmao,et al."Application of 10-ethyl-acridine-3-sulfonyl chloride for HPLC determination of aliphatic amines in environmental water using fluorescence and APCI-MS".JOURNAL OF SEPARATION SCIENCE (2009).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[You, Jinmao]的文章
[Zhao, Huaixin]的文章
[Sun, Zhiwei]的文章
百度学术
百度学术中相似的文章
[You, Jinmao]的文章
[Zhao, Huaixin]的文章
[Sun, Zhiwei]的文章
必应学术
必应学术中相似的文章
[You, Jinmao]的文章
[Zhao, Huaixin]的文章
[Sun, Zhiwei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。