Knowledge Management System of Northwest Institute of Plateau Biology, CAS
Analysis for Flavonoids in Bee Pollens by Capillary Electrophoresis | |
LU Ting ; Edward P C Lai ; Jorn C C Yu ; HU Fengzu | |
2006 | |
发表期刊 | 食品科学 ; LU Ting,Edward P C Lai,Jorn C C Yu,HU Fengzu.Analysis for Flavonoids in Bee Pollens by Capillary Electrophoresis.食品科学,2006,27(12):582-587 |
摘要 | A capillary electrophoresis (CE) method has been developed for the determination of six bioactive flavonoids that are commonly found in health foods: hesperidin, hyperin, isorhamnetin, kaempferol, quercetin and rutin. The effects of several parameters, such as pH, buffer concentration, separation voltage and UV detector wavelength, were investigated to find the optimal conditions. Using a HbBCh-NaiB-iO? buffer (pH 9.2), the analytes can be separated within 8 min. The relative standard deviations of migration times in eight injections were between 0.77% and 0.93%, and those of the peak areas ranged from 3.8% to 8.6%. A high reproducibility and excellent linearity was observed over two orders of magnitude, with detection limits (S/N = 3) ranging from 0.34ug ml to 2.9ug ml for all the six analytes. Recoveries ranged from 80.4 % to 113.9 %. The new method is simple, reproducible and sensitive. No solid phase extraction for sample pretreatment is necessary. Analysis results are accurate in application to bee pollens.; A capillary electrophoresis (CE) method has been developed for the determination of six bioactive flavonoids that are commonly found in health foods: hesperidin, hyperin, isorhamnetin, kaempferol, quercetin and rutin. The effects of several parameters, such as pH, buffer concentration, separation voltage and UV detector wavelength, were investigated to find the optimal conditions. Using a HbBCh-NaiB-iO? buffer (pH 9.2), the analytes can be separated within 8 min. The relative standard deviations of migration times in eight injections were between 0.77% and 0.93%, and those of the peak areas ranged from 3.8% to 8.6%. A high reproducibility and excellent linearity was observed over two orders of magnitude, with detection limits (S/N = 3) ranging from 0.34ug ml to 2.9ug ml for all the six analytes. Recoveries ranged from 80.4 % to 113.9 %. The new method is simple, reproducible and sensitive. No solid phase extraction for sample pretreatment is necessary. Analysis results are accurate in application to bee pollens. |
文献类型 | 期刊论文 |
条目标识符 | http://210.75.249.4/handle/363003/54868 |
专题 | 中国科学院西北高原生物研究所 |
推荐引用方式 GB/T 7714 | LU Ting,Edward P C Lai,Jorn C C Yu,et al. Analysis for Flavonoids in Bee Pollens by Capillary Electrophoresis[J]. 食品科学, LU Ting,Edward P C Lai,Jorn C C Yu,HU Fengzu.Analysis for Flavonoids in Bee Pollens by Capillary Electrophoresis.食品科学,2006,27(12):582-587,2006. |
APA | LU Ting,Edward P C Lai,Jorn C C Yu,&HU Fengzu.(2006).Analysis for Flavonoids in Bee Pollens by Capillary Electrophoresis.食品科学. |
MLA | LU Ting,et al."Analysis for Flavonoids in Bee Pollens by Capillary Electrophoresis".食品科学 (2006). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论