NWIPB OpenIR
13-Plex UHPLC-MS/MS Analysis of Hexanal and Heptanal Using Multiplex Tags Chemical Isotope Labeling Technology
Hu, Jingwen; Chen, Shi-En; Zhu, Shuyun; Jia, Wenhui; Sun, Jing; Zhao, Xian-En; Liu, Huwei
2020
发表期刊JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY
卷号31期号:9
摘要In this work, a new series of chemical isotope labeling reagents, levofloxacin-hydrazide-based mass tags (LHMTs) named as LHMT359/360/361/362/363/364/365/366/373/375/376/378/379/381 were first designed and synthesized for the high-throughput analysis of potential biomarkers containing hexanal and heptanal of lung cancer. We exploited a new core structure of levofloxacin-d(3), which significantly enhanced the multiplexing capability. Among them, LHMT359 was used for labeling standard compounds as internal standards for quantification. Using LHMT373-heptanal as dummy template, dummy magnetic molecularly imprinted polymers (DMMIPs) were prepared for magnetic dispersive solid-phase extraction after derivatization procedure. Other 12 LHMTs were established for high-throughput labeling hexanal and heptanal in human serum samples. The presynthesized DMMIPs can selectively extract LHMTs-derivatives of hexanal and heptanal from equally mixed derivatization solutions. The enriched derivatives of hexanal and heptanal were quantified by ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). A single UHPLC-MS/MS run enabled simultaneously quantifying hexanal and heptanal from 12 serum samples only within 2 min. The limits of detection were all 0.5 pM for hexanal and heptanal. The accuracies from human serum samples ranged from -10.2% to +11.0% with the intra- and interday precisions less than 11.3%. Meanwhile, this method was successfully applied for the analysis of hexanal and heptanal in serum samples from healthy people and lung cancer patients. The results show that this method has the significant advantages of high sensitivity, accuracy, selectivity, and analysis-throughput. The method application indicates that the developed method is promising in the screening of suspected lung cancer patients.
关键词aldehydes chemical isotope labeling multiplex mass tags magnetic molecularly imprinted polymers liquid chromatography tandem mass spectrometry lung cancer biomarkers
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/60255
专题中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Hu, Jingwen,Chen, Shi-En,Zhu, Shuyun,et al. 13-Plex UHPLC-MS/MS Analysis of Hexanal and Heptanal Using Multiplex Tags Chemical Isotope Labeling Technology[J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,2020,31(9).
APA Hu, Jingwen.,Chen, Shi-En.,Zhu, Shuyun.,Jia, Wenhui.,Sun, Jing.,...&Liu, Huwei.(2020).13-Plex UHPLC-MS/MS Analysis of Hexanal and Heptanal Using Multiplex Tags Chemical Isotope Labeling Technology.JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,31(9).
MLA Hu, Jingwen,et al."13-Plex UHPLC-MS/MS Analysis of Hexanal and Heptanal Using Multiplex Tags Chemical Isotope Labeling Technology".JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 31.9(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Hu, Jingwen]的文章
[Chen, Shi-En]的文章
[Zhu, Shuyun]的文章
百度学术
百度学术中相似的文章
[Hu, Jingwen]的文章
[Chen, Shi-En]的文章
[Zhu, Shuyun]的文章
必应学术
必应学术中相似的文章
[Hu, Jingwen]的文章
[Chen, Shi-En]的文章
[Zhu, Shuyun]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。