NWIPB OpenIR
Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent
Zhang, Shijuan ; Yu, Zhaoqiang ; Hu, Na ; Sun, Yuanpeng ; Suo, Yourui ; You, Jinmao
2014-05-01
发表期刊FOOD CONTROL ; Zhang, SJ; Yu, ZQ; Hu, N; Sun, YP; Suo, YR; You, JM.Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent,FOOD CONTROL,2014,39():25
摘要A new and sensitive pre-column derivatization method was developed for the analysis of melamine leached from tableware by high performance liquid chromatography (HPLC) with fluorescence detection. The HPLC sensitivity was greatly enhanced by introducing 10-methyl-acridone-2-sulfonyl chloride (MASC) with excellent fluorescence property into the melamine molecule. Meanwhile, derivatization also greatly increased the hydrophobicity of melamine. Therefore, the common reversed phase column can be used for the HPLC analysis of highly hydrophilic melamine. The detection limit obtained by the proposed method was lower than 0.40 mu g/L. This is the first time that HPLC with fluorescence detection was applied to the analysis of melamine. The proposed method was successfully applied to the analysis of melamine leached from tableware. The results indicated that the leaching of melamine from tableware was obvious when hot water or milk was added. (C) 2013 Elsevier Ltd. All rights reserved.; A new and sensitive pre-column derivatization method was developed for the analysis of melamine leached from tableware by high performance liquid chromatography (HPLC) with fluorescence detection. The HPLC sensitivity was greatly enhanced by introducing 10-methyl-acridone-2-sulfonyl chloride (MASC) with excellent fluorescence property into the melamine molecule. Meanwhile, derivatization also greatly increased the hydrophobicity of melamine. Therefore, the common reversed phase column can be used for the HPLC analysis of highly hydrophilic melamine. The detection limit obtained by the proposed method was lower than 0.40 mu g/L. This is the first time that HPLC with fluorescence detection was applied to the analysis of melamine. The proposed method was successfully applied to the analysis of melamine leached from tableware. The results indicated that the leaching of melamine from tableware was obvious when hot water or milk was added. (C) 2013 Elsevier Ltd. All rights reserved.
文献类型期刊论文
条目标识符http://210.75.249.4/handle/363003/17006
专题中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Zhang, Shijuan,Yu, Zhaoqiang,Hu, Na,et al. Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent[J]. FOOD CONTROL, Zhang, SJ; Yu, ZQ; Hu, N; Sun, YP; Suo, YR; You, JM.Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent,FOOD CONTROL,2014,39():25,2014.
APA Zhang, Shijuan,Yu, Zhaoqiang,Hu, Na,Sun, Yuanpeng,Suo, Yourui,&You, Jinmao.(2014).Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent.FOOD CONTROL.
MLA Zhang, Shijuan,et al."Sensitive determination of melamine leached from tableware by reversed phase high-performance liquid chromatography using 10-methyl-acridone-2-sulfonyl chloride as a pre-column fluorescent labeling reagent".FOOD CONTROL (2014).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Shijuan]的文章
[Yu, Zhaoqiang]的文章
[Hu, Na]的文章
百度学术
百度学术中相似的文章
[Zhang, Shijuan]的文章
[Yu, Zhaoqiang]的文章
[Hu, Na]的文章
必应学术
必应学术中相似的文章
[Zhang, Shijuan]的文章
[Yu, Zhaoqiang]的文章
[Hu, Na]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。