Knowledge Management System of Northwest Institute of Plateau Biology, CAS
LC determination of amino acids in rat plasma with fluorescence detection: Application to exercise physiology | |
Zhao, Xianen ; Suo, Yourui | |
2008-03-01 | |
发表期刊 | CHROMATOGRAPHIA ; Zhao Xianen, Suo Yourui.LC determination of amino acids in rat plasma with fluorescence detection: Application to exercise physiology.CHROMATOGRAPHIA,2008,67(5-6):375-382 |
摘要 | An LC method for the determination of 20 amino acids (AAs), using 1,2-Benzo-3,4-dihydrocarbazole-9-ethyl chloroformate (BCEOC) as fluorescent labeling reagent, has been validated and applied for the analysis of AAs in rat plasma at three different states concerning exercise physiology. Identification of AA derivatives was carried out by LC-MS with electrospray ion (ESI), and the MS-MS cleavage mode of the representative tyrosine (Tyr) derivative was analyzed. Gradient elution on a Hypersil BDS C-18 column gave good separation of the derivatives. Excellent linear responses were observed and good compositional data could be obtained from as little as 50-200 mu L of plasma samples. The contents of 20 AAs in rat plasma of three groups (24 rats, group A: quiet state, group B: at exercising exhaust, group C: 12 h after exercising exhaust) exhibited evident difference corresponding to the physiological states. Facile BCEOC derivatization coupled with LC-FLD-ESI-MS analysis allowed the development of a highly sensitive method for the quantitative analysis of trace level of AAs from plasma or other biochemical samples.; An LC method for the determination of 20 amino acids (AAs), using 1,2-Benzo-3,4-dihydrocarbazole-9-ethyl chloroformate (BCEOC) as fluorescent labeling reagent, has been validated and applied for the analysis of AAs in rat plasma at three different states concerning exercise physiology. Identification of AA derivatives was carried out by LC-MS with electrospray ion (ESI), and the MS-MS cleavage mode of the representative tyrosine (Tyr) derivative was analyzed. Gradient elution on a Hypersil BDS C-18 column gave good separation of the derivatives. Excellent linear responses were observed and good compositional data could be obtained from as little as 50-200 mu L of plasma samples. The contents of 20 AAs in rat plasma of three groups (24 rats, group A: quiet state, group B: at exercising exhaust, group C: 12 h after exercising exhaust) exhibited evident difference corresponding to the physiological states. Facile BCEOC derivatization coupled with LC-FLD-ESI-MS analysis allowed the development of a highly sensitive method for the quantitative analysis of trace level of AAs from plasma or other biochemical samples. |
文献类型 | 期刊论文 |
条目标识符 | http://210.75.249.4/handle/363003/45627 |
专题 | 中国科学院西北高原生物研究所 |
推荐引用方式 GB/T 7714 | Zhao, Xianen,Suo, Yourui. LC determination of amino acids in rat plasma with fluorescence detection: Application to exercise physiology[J]. CHROMATOGRAPHIA, Zhao Xianen, Suo Yourui.LC determination of amino acids in rat plasma with fluorescence detection: Application to exercise physiology.CHROMATOGRAPHIA,2008,67(5-6):375-382,2008. |
APA | Zhao, Xianen,&Suo, Yourui.(2008).LC determination of amino acids in rat plasma with fluorescence detection: Application to exercise physiology.CHROMATOGRAPHIA. |
MLA | Zhao, Xianen,et al."LC determination of amino acids in rat plasma with fluorescence detection: Application to exercise physiology".CHROMATOGRAPHIA (2008). |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Zhao, Xianen]的文章 |
[Suo, Yourui]的文章 |
百度学术 |
百度学术中相似的文章 |
[Zhao, Xianen]的文章 |
[Suo, Yourui]的文章 |
必应学术 |
必应学术中相似的文章 |
[Zhao, Xianen]的文章 |
[Suo, Yourui]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论